期刊文献+

吸收塔泄漏原因分析及处理措施 被引量:1

Cause Analysis and Treatment Measures of Absorption Tower Leakage
下载PDF
导出
摘要 超低排放形势下FGD氨法脱硫作为化工企业成熟、高效、操作简单控制SO2的有效方式,运行中关键设备吸收塔会出现各种异常情况。介绍了中新化工锅炉超低排放吸收塔出现的塔体泄漏情况,及对吸收塔泄漏的情况进行深入分析,采取有效措施,确保超低排放装置安全运行。 Under the situation of ultra-low emission,FGD ammonia desulfurization is an effective way for chemical enterprises to control SO2 with maturity,high efficiency and simple operation,and there will be various abnormal situations in the operation of key equipment absorption tower.This paper introduces the leakage of absorption tower body in ultra-low emission absorption tower of Zhongxin chemical boiler,analyzes the leakage of absorption tower,and takes effective measures to ensure the safe operation of ultra-low emission device.
作者 冯虎林 Feng Hu-lin
出处 《化工设计通讯》 CAS 2020年第7期59-60,共2页 Chemical Engineering Design Communications
关键词 超低排放 吸收塔 泄漏 原因分析 处理措施 ultra-low emission absorption tower leakage cause analysis treatment measure
  • 相关文献

参考文献2

二级参考文献2

共引文献28

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部