摘要 目的探讨心电连接器的改进及其临床应用效果。方法针对改进前心电连接器在使用过程中存在的问题,设计改进型心电连接器并应用于临床。比较改进前后心电连接器耗损率、心电图波形稳定性、经外周静脉置入中心静脉导管(PICC)置管到位率。结果改进型心电连接器组的耗损率、心电图波形稳定性、PICC尖端最佳位置的到位率均显著优于改进前心电连接器组(P<0.05或P<0.01)。结论改进型心电连接器结构设计更合理,性能更稳定,PICC尖端定位效果更优,经久耐用,且其一器多用的特点实现了与多种心电设备的连接。 Objective To explore the improvement method of electrocardiograph connector and its clinical application effect.Methods The improved electrocardiograph connector was designed and applied in clinic according to the problems existing in unimproved electrocardiograph connector.The wear-out rate of electrocardiograph connector,the stability of electrocardiograph waveform and cathetering in place rate of peripherally inserted central catheter(PICC)tube before and after improvement were compared.Results The wear-out rate,the stability of ECG waveform and the cathetering in place rate of PICC of the improved ECG connector were better than those of unimproved electrocardiograph connector(P<0.05 or P<0.01).Conclusion The structure design of the improved electrocardiograph connector is more reasonable,and its performance is stable.The effect of the PICC tip positioning is better,and it is durable,and the feature of the machine with multiple purpose realizes the connection with many electrocardiograph equipments.
作者 陈蓉 任晓敏 俞晔 过瑾 陆培华 李丽 CHEN Rong;REN Xiaomin;YU Ye;GUO Jin;LU Peihua;LI Li(Nursing Department,Wuxi People′s Hospital Affiliated to Nanjing Medical University,Wuxi,Jiangsu,214023;Outpatient Nursing Department of Intravenous Infusion,Wuxi People′s Hospital Affiliated to Nanjing Medical University,Wuxi,Jiangsu,214023;Devices Department,Wuxi People′s Hospital Affiliated to Nanjing Medical University,Wuxi,Jiangsu,214023;Department of Cardiac Function,Wuxi People′s Hospital Affiliated to Nanjing Medical University,Wuxi,Jiangsu,214023;Scientific Research Office,Wuxi People′s Hospital Affiliated to Nanjing Medical University,Wuxi,Jiangsu,214023)
出处 《实用临床医药杂志》 CAS 2020年第8期14-17,22,共5页 Journal of Clinical Medicine in Practice
基金 江苏省无锡市卫生计生委科研项目(MS201636)。
关键词 经外周静脉置入中心静脉导管 尖端定位 心电描记 心电连接器 改进 peripherally inserted central catheter tip positioning electrocardiography electrocardiography connector improvement
  • 相关文献

参考文献10

二级参考文献102

  • 1朱冰船.心电监护产生伪差、误判的原因及分析与对策[J].当代护士(中旬刊),2004,11(8):33-35. 被引量:7
  • 2张帷,张石,鲍喜荣,张平,董建威.便携式心电监护仪前置放大电路和抗干扰的设计[J].医疗设备信息,2005,20(10):7-9. 被引量:15
  • 3张纯桃,周笙华,陈翠芬.动态心电监测中常见干扰原因及心电图分析[J].护理学杂志(综合版),2005,20(12):22-23. 被引量:7
  • 4莫平,卢振和,何荣芝,郑志远,钱耀亮,赵雾红.中心静脉导管位置与新型静脉内心电图[J].临床麻醉学杂志,2007,23(7):569-571. 被引量:14
  • 5Vesely TM.Central venous catheter tip position:a continuing controversy [J]. J Vasc Interv RadioI,2003,14(5):527-534.
  • 6Racadio JM,Doellman DA,Johnson ND,et al.Pediatfic peripherally inserted central catheters:complication rates related to catheter tip location[J]. Pediatrics,2001,107(2) :E28.
  • 7Kearns PJ,Coleman S,Wehner JH.Complications of long arm-catheters:a randomized trial of central vs peripheral tip loeatian[JJ. J Parenter Enteral Nutr. 1996,20 ( 1 ) : 20-24.
  • 8Frey AM. Pediatric peripherally inserted centra/ catheter program report:a summary of 4,536 catheter daysEJ]. J lntraven Nuts,1995,18 (6):280-291.
  • 9Gamulka B,Mendoza C,Connolly B.Evaluation of a unique,aurse-insert- ed,peripheraUy inserted central catheter program[J]. Pediatrics,2005,1 t5 (6) : 1602-1606.
  • 10Ohki Y,Tabata M,Kuwashima M,et al. Ultrasonographic detection of very thin pcrcutaneous central venous catheter in neonates[J]. Acta Pacdiatr, 2000,89 ( 11 ) : 1381 - 1384.

共引文献261

同被引文献30

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部