摘要 针对球面超大曲率半径测量中存在的测量精度低、抗环境干扰能力差的难题,研制了一套激光差动共焦反射式超大曲率半径测量系统。该系统采用反射式测量光路,利用差动共焦响应曲线对被测件的猫眼和反射位置进行高精度定位,并用测长干涉仪记录位置信息,最后结合物镜顶焦距解算出超大曲率半径值。理论分析与实验表明,该系统定焦精度高,测量范围大,抗环境干扰能力强,相对测量误差优于2×10^-4,-15 m超大曲率半径测量结果的重复性可达1.2×10^-4,实现了超大曲率半径的高精度测量。 To solve the low measurement accuracy and poor resistance to environmental interference in the ultra-large radius measurement field,a laser reflection differential confocal ultra-large radius measurement system is developed.The system adopts reflective measuring optical path,and uses the curve of the differential confocal system to precisely locate the cat's-eye and reflection positions of the tested device.The displacement information of the tested device is recorded by interferometer,and then combined with the vertex focal length of the objective lens to calculate the ultra-large radius value.Theoretical analysis and experimental results show that the system has high focusing accuracy and large measurement range and high anti-environment interference ability,and its relative measurement error is less than 2×10^-4,and its measuring repeatability reaches at 1.2×10^-4 for-15 m ultra-large radius,and the system realizes the highprecision measurement of ultra-large curvature radius.
作者 卜乙禄 李琦 李彦宏 邱丽荣 周桃庚 赵维谦 Bu Yilu;Li Qi;Li Yanhong;Qiu Lirong;Zhou Taogeng;Zhao Weiqian(Beijing Key Lab for Precision Optoelectronic Measurement Instrument and Technology,School of Optics and Photonics,Beijing Institute of Technology,Beijing 100081,China)
出处 《电子测量与仪器学报》 CSCD 北大核心 2020年第5期1-8,共8页 Journal of Electronic Measurement and Instrumentation
基金 国家重点研发计划课题(2017YFA0701203)项目资助。
关键词 差动共焦 反射式 超大曲率半径 定焦 测量系统 differential confocal reflection ultra-large radius focusing measurement system
  • 相关文献

参考文献10

二级参考文献167

共引文献60

同被引文献64

引证文献7

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部