摘要 风机房内设备运行时产生强烈的中低频噪声直接向外界传播,严重影响了厂区内的工作环境。针对云南某冶炼企业GM风机房、SO2风机房的实际情况,结合风机房的改造工程制定合理的噪声控制方案,帮助企业有效地解决噪声污染的问题。 The intense middle and low-frequency noise,which was produced by running equipment in ventilator rooms,was spread out directly.It has a strong impact on the working environment inside the factory area.Aiming at the actual situations of GM ventilator rooms and SO2 ventilator rooms in Yunnan smelting enterprise,the author makes reasonable schemes for noising control that combined with the improvement project of ventilator rooms,to help enterprise to solve the problems of noise pollution effectively.
作者 杨桃艳 赵宏明 李四梅 Yang Taoyang;Zhao Hongming;Li Simei(Kunming Engineering&Research Institute of Nonferrous Metallurgy Co.,Ltd.,Kunming 650051,China)
出处 《有色金属设计》 2020年第2期35-39,共5页 Nonferrous Metals Design
关键词 风机房 改造工程 噪声治理 Ventilator room Improvement project Noise control