摘要
在桂林空管临时塔台项目中,应急甚高频设备配置为英国PAE T6TR收发一体机,在键控PTT时,发现电台与飞坤内话席位均出现啸叫干扰。论文通过分析电台啸叫产生原理,提出了相应的解决方案。
In the Guilin Air Traffic Control Temporary Tower Project,the British PAE T6TR transceiver is configured as the emergency VHF equipment.When PTT is keyed,it is found that both the radio and the Feikun interphone seats have whistle interference.Through the analysis of the generating principle of radio's whistle,this paper puts forward the corresponding solutions.
作者
易振宁
YI Zhen-ning(Guilin Air Traffic Management Station of Civil Aviation of China,Guilin 541000,China)
出处
《中小企业管理与科技》
2020年第17期190-191,共2页
Management & Technology of SME
关键词
甚高频
啸叫干扰
啸叫抑制
VHF
whistle interference
whistle suppression