期刊文献+

严寒地区近零能耗建筑太阳能新风预热系统供暖效果实测研究 被引量:4

EXPERIMENTAL STUDY ON SOLAR PREHEATING SYSTEM USED IN NEARLY-ZERO-ENERGY BUILDING IN SEVERE COLD AREA
下载PDF
导出
摘要 基于青海省某近零能耗建筑冬季测试结果,对测试对象的室内热环境、常规能耗及太阳能保证率等主要指标结果及变化规律进行分析,验证太阳能与新风预热耦合供热系统在该类建筑中的应用效果。测试结果表明,在严寒地区近零能耗建筑中,通过采用补充热源加热,太阳能与新风预热耦合供热系统可有效维持室内热环境稳定性,太阳能保证率至少可达31%以上。 Based on field experiments in a nearly-zero-energy building in Qinghai province,the combination of solar heating and fresh air systems is evaluated by analyzing the indoor thermal environment,energy consumaption and solar fraction.Evaluation result indicate the combination of solar heating and fresh air system can build a steady indoor thermal environment in a nearly-zero-energy building in the severe cold area by using a supplemental heating system.The solar fraction can be over 31%at least.
作者 马文生 郭强 黄霆鹤 刘景东 杨诗薇 Ma Wensheng;Guo Qiang;Huang Tinghe;Liu Jingdong;Yang Shiwei(China Academy of Building Research,Bejing 100013,China)
出处 《太阳能学报》 EI CAS CSCD 北大核心 2020年第6期370-374,共5页 Acta Energiae Solaris Sinica
基金 “十三五”国家重点研发计划项目“近零能耗建筑技术体系及关键技术开发”(2017YFC0702600) 住房和城乡建设部科学计划项目“北方地区清洁取暖技术适用性评价体系研究”(2017-K11-005)。
关键词 可再生能源 太阳能供暖 预热 严寒地区 实测 renewable energy solar heating preheating severe cold area experiments