摘要
文中通过对国内现阶段卡套管接头检测行业所采用的检测标准GB/T 3765—2008与美国标准ASTM F1387—99(2012)进行对比分析,重点介绍两个标准中试验条件及试验方法的对比分析,得出两个检测标准所要求事项是有差异的,此对比能为卡套管接头型式试验标准选择及运用提供参考。
In this paper,the testing standard GB/T 3765—2008 adopted by the domestic ferrule pipe joint testing industry at present was compared with the American standard ASTM F1387—99(2012).This paper focuses on the comparative analysis of test conditions and test methods in the two standards.It is concluded that there are differences in the requirements of the two testing standards,which can provide reference for the selection and application of the type test standard of ferrule pipe joints.
作者
张弘一
李鹏程
付明东
时会强
宋洋
ZHANG Hong-yi;LI Peng-cheng;FU Ming-dong;SHI Hui-qiang;SONG Yang(Guoyi Testing Technology(Shenyang)Co.,Ltd.,Shenyang 110043,China)
出处
《管道技术与设备》
CAS
2020年第4期52-55,共4页
Pipeline Technique and Equipment
关键词
卡套管接头
重复安装
压力检验
循环脉冲
cartridge pipe joints
repeat installation
pressure inspection
cyclic pulse