摘要
本文通过对某款带有独立变温室的法式冰箱测试结果进行分析,借助CFD仿真工具对改进方案进行仿真模拟,通过对仿真结果的分析对比,确定恒温改进方案。然后结合实验测试,验证新方案符合性能要求,为冰箱变温室恒温方案提出新思路。
In this paper,the test results of a French refrigerator with independent variable greenhouse are analyzed,and the improved scheme is simulated with CFD simulation tools.Through the analysis and comparison of the simulation results,the constant temperature improvement scheme is determined.Then combined with the experimental test,the new scheme is verified to meet the performance requirements,and a new idea is put forward for the constant temperature scheme of refrigerator changing greenhouse.
出处
《日用电器》
2020年第7期72-75,共4页
ELECTRICAL APPLIANCES
关键词
变温室
CFD仿真
恒温
variable greenhouse
CFD simulation
constant temperature