期刊文献+

离子色谱法测定农用硫酸铵中4种杂质阴离子 被引量:6

Determination of Four Impurity Anions in Agricultural Ammonium Sulfate by Ion Chromatography
下载PDF
导出
摘要 建立了离子色谱法同时测定农用硫酸铵中氟、氯、溴、硫氰酸盐的分析方法。样品经水提取,Ba离子柱净化后,离子色谱法测定。4种阴离子浓度在各自线性范围内与相应峰面积呈线性关系,相关系数r>0.999,加标回收率为80.2%~112%,相对标准偏差(RSD)为0.25%~9.1%。称样量为0.1 g时,氟、氯的方法检出限为10 mg/kg;溴、硫氰酸盐方法检出限为20 mg/kg。样品前处理简单、快捷,重复性及加标回收率均能达到检测分析要求,可以应用于农用硫酸铵中杂质阴离子的检测。 A method for the analysis of fluorine,chlorine,bromine and thiocyanate in agricultural ammonium sulfate by ion chromatography was established.The samples were extracted by water,and purified by Ba ion column,then detected by ion chromatography.There is a linear relationship between the concentration of four anions and the peak area,the correlation coefficient r>0.999,the recovery rate was 80.2%—112%,and the precision(RSD)was 0.25%—9.1%.When the sample weight is 0.1 g,the detection limit of fluorine and chlorine is 10 mg/kg,and that of bromine and thiocyanate is 20 mg/kg.The method is simple,fast and reproducible,and recovery can meet the requirements of analysis.This method can be applied to the detection of impurity anions in agricultural ammonium sulfate.
作者 刘爽 张娟 徐楠 凡书杰 徐吉远 孙文丹 尹畅 LIU Shuang;ZHANG Juan;XU Nan;FAN Shujie;XU Jiyuan;SUN Wendan;YIN Chang(Shandong Institute of Product Quality Inspection,Jinan,Shandong 250100,China)
出处 《中国无机分析化学》 CAS 2020年第4期36-40,共5页 Chinese Journal of Inorganic Analytical Chemistry
基金 国家重点研发计划项目(2016YFF0201801)。
关键词 农用硫酸铵 阴离子 离子色谱 agricultural ammonium sulfate anion ion chromatography