摘要 采用试验与系统仿真相结合的方法,对R32制冷剂家用变频空调器在APF性能匹配过程中出现的额定中间工况性能不良现象进行分析。通过对制冷剂侧和空气侧的换热进行分析,明确R32空调系统额定中间工况性能偏低的主要原因。并对室内机换热器管路流程及管径进行优化设计,使得额定中间制冷工况制冷量提升4%左右,且空调系统APF提高3.8%。 By means of the experiment and simulation methods,the poor performance that appears under rated intermediate operating conditions during the process of performance matching of APF for R32 household frequency-conversion air conditioner is analyzed.The main reason for the poor performance under rated intermediate operating condition of R32 air-conditioning system is clarified by the analysis on the heat exchange between the refrigerant side and the air side.After the optimized designs of the indoor unit heat exchanger's pipeline layout and pipe diameter,the cooling capacity under the rated intermediate cooling operating condition is improved by about 4%,and the APF of the air-conditioning system is increased by 3.8%.
作者 刘春慧 张蕾 Liu Chunhui;Zhang Lei(Shanghai Highly Electrical Appliances Co.,Ltd.)
出处 《制冷与空调》 2020年第7期31-34,共4页 Refrigeration and Air-Conditioning
关键词 空调器 换热器 额定中间工况 APF 小管径 流程 air conditioner heat exchanger rated intermediate operating condition APF small pipe diameter pipeline layout
  • 相关文献

参考文献3

二级参考文献22

  • 1吴晓敏,李辉,龚鹏,王维城,李瑞霞.水平微肋管内蒸发及冷凝换热性能研究[J].工程热物理学报,2006,27(3):460-462. 被引量:20
  • 2武永强,罗忠.R410A和R22在水平强化管内的蒸发和冷凝性能[J].工程热物理学报,2006,27(2):292-294. 被引量:8
  • 3汪振策,丁国良,胡海涛,王凯建.R410A-油混合物在7mm C形光管内蒸发换热特性及关联式[J].机械工程学报,2007,43(6):76-80. 被引量:1
  • 4Hung Pham et al. , R32 and HFO as low - GWP refrigerants for air conditioning, International Refrigeration and Air Condition- ing Conference at Purdue, 2012.
  • 5Jee Young Shin,Min Soo Kim,Sung Tack Ro. Experimental study on forced convective boiling heat transfer of pure refrigerants and refrigerant mixtures in a horizontal tube[J].International Journal of Refrigeration-Revue Internationale du Froid,1997.267-275.
  • 6Dongsoo Jung,Kwangyong An,Jinseok Park. Nucleate boiling heat transfer coefficients of HCFC22,HFC134a,HFC125,and HFC32 on various enhanced tubes[J].International Journal of Refrigeration-Revue Internationale du Froid,2004.202-206.
  • 7Anowar Hossain Md,Onaka Yoji,Akio Miyara. Experimental study on condensation heat transfer and pressure drop in horizontal smooth tube for R1234ze(E),R32 and R410A[J].International Journal of Refrigeration-Revue Internationale du Froid,2012.
  • 8Wang H S,Rose J W,Honda H. Condensation of refrigerants in horizontal micro-fin tubes:comparison of correlations for frictional pressure drop[J].International Journal of Refrigeration-Revue Internationale du Froid,2003.461-472.
  • 9Marko Matkovic,Alberto Cavallini,Davide Del Col. Experimental study on condensation heat transfer inside a single circular mini-channel[J].International Journal of Heat and Mass Transfer,2009.2311-2323.
  • 10Cavallini A,Censi G,Del Col D. Rossetto.Experimental investigation on condensation heat transfer and pressure drop of new HFC refrigerants (R134a,R125,R32,R410A,R236ea) in a horizontal smooth tube[J].International Journal of Refrigeration-Revue Internationale du Froid,2001.73-87.

共引文献23

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部