摘要
本文通过对铁路车辆空调制冷剂的流体特点进行分析,结合实际工作经验,确定了利用氦气进行空调制冷管路检漏的新方法,并通过换算了泄漏率的标准值,明确了检漏操作的有效方法和实施效果。
Through analyzing the fluid characteristics of railway vehicle air conditioning refrigerant and combining with practical work experience,determine a new refrigerating pipeline's leakage detection method by helium gas.Through converting the standard value of leakage rate,clarify the effective method and implementation effect of leakage detection operation.
作者
赵文浩
Zhao Wenhao(CRRC Dalian Institute Co.,Ltd.)
出处
《制冷与空调》
2020年第7期91-92,共2页
Refrigeration and Air-Conditioning
关键词
铁路车辆
空调
氦气
检漏
railway vehicle
air conditioner
helium
leakage detection