对厌氧氨氧化的脱氮效果受HRT、溶解氧和有机物的影响情况进行研究。采用人工配水,控制pH为7.5~8.0,温度为(35±1)℃,进水NH4+-N、NO2--N质量比为1∶1.32,通过进水脱氧和不脱氧改变溶解氧的浓度,有机物影响试验采用厌氧瓶静态试验。以总氮平均负荷为0.472 kg/(m3·d)为前提条件时,得到复合式UASB厌氧氨氧化反应器的最适宜HRT为12 h;改变条件,当溶解氧为0.7~1.0 mg/L,虽然反应受到影响,但还可以稳定运行;将DO降到(0.2±0.1) mg/L,经过一段时间的反应,厌氧氨氧化反应的处理效果恢复;再次改变进水COD为50~150 mg/L,NH4+-N去除率可维持在75%以上,NO2--N去除率可达90%以上,COD去除率最低可达到74%,仍保持在较高水平。对于厌氧氨氧化脱氮效果的影响,HRT、溶解氧较大,有机物较小。
HRT,dissolved oxygen and organic matter were studied on the denitrification effect of ANAMMOX. Artificial water distribution was used in the test,and the pH,temperature,the mass ratio of NH4+-N/NO2--N in the water was 7.5-8.0,(35±1) ℃,1∶1.32. The concentration of dissolved oxygen is changed by deoxygenation and non-deoxygenation of the influent,and the anaerobic bottle static test is used for the organic matter influence test. Under the average load of total nitrogen of 0.472 kg/(m3·d),the optimum HRT for the compound UASB anaerobic ammonia oxidation reactor is 12 h. When the concentration of dissolved oxygen was 0.7-1.0 mg/L,although the reaction was affected,it could still operate stably. Then DO concentration was reduced to(0.2±0.1) mg/L,after a period of reaction time,the treatment effect of anaerobic ammonia oxidation was restored as usual. The mass concentration of influent COD was50-150 mg/L,while the removal rate of NH4+-N and NO2--N were maintained at more than 75% and 90%. Also,the removal rate of COD could reach 74% at the lowest level. In terms of the effect of anammox,HRT and dissolved oxygen are larger,while organic matter is smaller.
作者
李亚峰
于燿滏
杨嗣靖
马晨曦
Li Yafeng;Yu Yaofu;Yang Sijing;Ma Chenxi(School of Municipal and Environmental Engineering,Shenyang Jianzhu University,Shenyang 110168,China;Shenyang Water Supply&Drainage Prospecting Design Research Institute Co.,Ltd.,Shenyang 110000,China)
出处
《工业水处理》
CAS
CSCD
北大核心
2020年第8期27-31,共5页
Industrial Water Treatment
基金
水体污染控制与治理科技重大专项(2018ZX07601004-01)。