摘要
随着服役时间的增长,侵蚀环境下钢筋混凝土框架节点因钢筋发生不同程度的锈蚀而造成承载性能下降,严重影响建筑结构的安全使用。本文在已有钢筋混凝土框架节点抗剪强度理论模型的基础上,考虑钢筋锈蚀对框架节点受力性能的影响,建立锈蚀钢筋混凝土框架中节点受剪承载力计算公式。通过11组锈蚀钢筋混凝土节点试验数据,对建议理论模型进行验证。研究结果表明,锈蚀钢筋混凝土节点受剪承载力试验值与理论计算值之比的平均值为0.951,方差为0.075,二者吻合较好,本文建议的计算方法可用于锈蚀钢筋混凝土框架中节点承载力分析。
With the increasing of service time,due to the corrosion of steel bars,the bearing performance of reinforced concrete frame joints under erosion environment is reduced,which seriously affects the safety of building structures.Based on existing theoretical models of shear strength of reinforced concrete frame joints,the calculation formula of shear strength of corroded reinforced concrete frame joints was proposed by considering the effect of steel bars corrosion.The test results of 11 sets of corroded reinforced concrete joints were used to validate the suggested model.The results show that the ratios between test values and calculated values of shear strength of corroded joints is 0.951,and the variance is 0.075,which is in good agreement.The calculation method proposed in this paper can analyze the bearing capacity of corroded reinforced concrete frame joints.
作者
邢国华
武名阳
丁远泽
常召群
王志萌
Xing Guohua;Wu Mingyang;Ding Yuanze;Chang Zhaoqun;Wang Zhimeng(School of Civil Engineering,Chang’an University,Xi’an 710061,China;School of Civil Engineering,Xinjiang University,Urumqi 830046,China)
出处
《震灾防御技术》
CSCD
北大核心
2020年第1期33-42,共10页
Technology for Earthquake Disaster Prevention
基金
新疆自治区自然科学基金(2018D01C038)。
关键词
混凝土结构
锈蚀
节点
抗剪强度
耦合作用
Concrete structures
Corrosion
Joints
Shear strength
Coupling effect