列管式换热器管束胀口泄漏分析

Leakage Analysis for Pipe Bundle of Tubular Exchanger
下载PDF
导出
摘要 本文针对压缩机列管式换热器管束胀口泄漏典型故障,从循环水质管控,管板材质和胀接工艺选择进行了详细分析,明确了缝隙腐蚀是造成胀口泄漏的主要原因。同时,提出了防止换热器发生缝隙腐蚀的具体措施。
出处 《石油和化工设备》 CAS 2020年第8期103-104,102,共3页 Petro & Chemical Equipment
  • 相关文献

参考文献1

二级参考文献11

  • 1B.T. Lu,J.L. Luo,Y.C. Lu.Effects of pH on lead-induced passivity degradation of nuclear steam generator tubing alloy in high temperature crevice chemistries[J].Electrochimica Acta.2013
  • 2J. Tan,Y.C. Lu,J.H. Xu,G.S. Luo.Mass transfer characteristic in the formation stage of gas–liquid segmented flow in microchannel[J].Chemical Engineering Journal.2012
  • 3M.L. Ungaro,R.M. Carranza,M.A. Rodriguez.Crevice Corrosion Study on Alloy 22 by Electrochemical Noise Technique[J].Procedia Materials Science.2012
  • 4Qian Hu,Guoan Zhang,Yubin Qiu,Xingpeng Guo.The crevice corrosion behaviour of stainless steel in sodium chloride solution[J].Corrosion Science.2011(12)
  • 5Jian Xu,Xinqiang Wu,En-Hou Han.Acoustic emission during pitting corrosion of 304 stainless steel[J].Corrosion Science.2011(4)
  • 6Jian Xu,Xinqiang Wu,En-Hou Han.Acoustic emission during the electrochemical corrosion of 304 stainless steel in H 2 SO 4 solutions[J].Corrosion Science.2010(1)
  • 7Hung-Kai Shu,Faisal M. Al-Faqeer,Howard W. Pickering.Pitting on the crevice wall prior to crevice corrosion: Iron in sulfate/chromate solution[J].Electrochimica Acta.2010(4)
  • 8A. Rauf,W.F. Bogaerts.Monitoring of crevice corrosion with the electrochemical frequency modulation technique[J].Electrochimica Acta.2009(28)
  • 9Glyn F. Kennell,Richard W. Evitts.Crevice corrosion cathodic reactions and crevice scaling laws[J].Electrochimica Acta.2009(20)
  • 10Glyn F. Kennell,Richard W. Evitts,Kevin L. Heppner.A critical crevice solution and IR drop crevice corrosion model[J].Corrosion Science.2008(6)

共引文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部