摘要 非线性系统存在随机偏差情况下,最优二步无迹卡尔曼滤波(OTSUKF)可以获得系统状态及偏差的最优估计,但是它要求随机偏差被准确地建模,而这在实际情况下很难做到。飞行器是一种典型的非线性系统,将惯性测量单元(IMU)的故障作为一种随机偏差处理,并且采用随机游走模型去描述故障。随机游走模型对故障进行建模的准确程度取决于随机游走模型的协方差与实际情况的匹配程度。基于OTSUKF的IMU故障诊断方法中,随机游走模型的协方差取的是一个常值矩阵,该矩阵的值是根据经验初始化的,但是在实际应用中较难初始化为一个与真实故障相匹配的矩阵。根据新息协方差匹配技术,在线自适应调整随机游走模型的协方差矩阵,提出了自适应二步无迹卡尔曼滤波(ATSUKF),并将该方法应用于飞行器IMU的故障诊断。仿真实验对比了OTSUKF和ATSUKF方法对飞行器IMU的故障诊断的效果,验证了所提出的自适应方法的有效性。 In the case of nonlinear systems with random bias,the Optimal Two-Stage Unscented Kalman Filter(OTSUKF)can obtain the optimal estimation of system state and bias.But it requires random bias to be accurately modeled,while it is always very difficult in actual situation because the aircraft is a typical nonlinear system.In this paper,the faults of the Inertial Measurement Unit(IMU)are treated as a random bias,and the random walk model is used to describe the fault.The accuracy of the random walk model depends on the degree of matching between the covariance of the random walk model and the actual situation.For the IMU fault diagnosis method based on OTSUKF,the covariance of the random walk model is assigned with a constant matrix,and the value of the matrix is initialized empirically.It is very difficult to select a matching matrix in practical applications.For this problem,in this paper,the covariance matrix of the random walk model is adaptively adjusted online based on the innovation covariance matching technique,and an adaptive Two-Stage Unscented Kalman Filter(ATSUKF)is proposed to solve the fault diagnosis problem of the IMU.The simulation experiment compares the IMU fault diagnosis performance of OTSUKF and ATSUKF,and verifies the effectiveness of the proposed adaptive method.
作者 何启志 章卫国 刘小雄 李伟楠 HE Qizhi;ZHANG Weiguo;LIU Xiaoxiong;LI Weinan(School of Automation, Northwestern Polytechnical University, Xi′an 710129, China;Shaanxi Provincial Key Laboratory of Flight Control and Simulation Technology, Xi′an 710129, China)
出处 《西北工业大学学报》 EI CAS CSCD 北大核心 2020年第4期806-813,共8页 Journal of Northwestern Polytechnical University
基金 国家自然科学基金(61573286,61374032)资助。
关键词 自适应卡尔曼滤波 二步卡尔曼滤波 无迹卡尔曼滤波 惯性测量单元 故障诊断 随机游走模型 仿真实验 adaptive Kalman filter two stage Kalman filter unscented Kalman filter inertial measurement unit fault diagnosis random walk model simulation experiment
  • 相关文献

参考文献1

共引文献1

同被引文献12

引证文献3

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部