摘要 鉴于废油再生提炼厂的废水具有高含油量、高COD值、难生物降解的特点,选择过滤-臭氧氧化-混凝沉淀-膜过滤组合工艺处理,并优化试验条件以达到经济高效的处理效果。结果表明,当pH为10,臭氧氧化2 h,PAC添加量为4 g/L,PAM的添加量为0.2 g/L时,组合工艺对废水的石油类物质含量和COD Cr的去除率分别达到93.9%和91.6%。 In view of the characteristics of high oil content,high COD value,and difficult biodegradation of waste water from a waste oil regeneration and extraction plant,the combined process of filtration-ozonation-coagulation-membrane filtration was selected and the experimental conditions were optimized to achieve economical and efficient treatment effects.The results showed that when pH was 10,ozonation time for 2 h,the addition of PAC for 4 g/L and PAM for 0.2 g/L,the removal rates of petroleum oil content and COD Cr in the wastewater by the combined process reached 93.9%and 91.6%,respectively.
作者 陈艺敏 陈建发 CHEN Yi-min;CHEN Jian-fa(School of Food Engineering,Zhangzhou Institute of Technology,Zhangzhou 363000,China;Fujian Fine Chemicals Application Technology Cooperation Center in Vocational Colleges,Zhangzhou 363000,China)
出处 《长春师范大学学报》 2020年第8期104-108,共5页 Journal of Changchun Normal University
基金 福建省中青年教师教育科研项目“废油提炼废水处理的关键技术研究”(JZ180816) 福建省科技计划项目“漳州市食品产业技术研究院创新平台建设”(2018N2002)。
关键词 高含油废水 臭氧氧化 混凝沉淀 膜过滤 high oil-containing wastewater ozonation coagulation membrane filtration