期刊文献+

催化裂化装置腐蚀检查与分析 被引量:1

Corrosion inspection and analysis in the catalytic cracking unit
下载PDF
导出
摘要 某炼油厂催化裂化装置分馏塔塔顶系统多次出现腐蚀泄漏,给装置长周期运行造成较大影响。为全面掌握催化裂化装置腐蚀情况和规律,在装置停工期间开展了腐蚀调查,对设备及管线进行全面腐蚀检查和定点测厚,对每台设备腐蚀形态和情况进行分析总结,查找腐蚀隐患点,为腐蚀工作开展和设备大检修提出建议。 Corrosion leakage occurred in the overhead system of a catalytic cracking unit for many times,which had a great impact on the long-term operation of the unit.In order to fully grasp the corrosion situation and law of catalytic cracking unit,corrosion investigation is carried out during unit shutdown,and comprehensive corrosion inspection and fixed-point thickness measurement for equipment and pipelines are carried out.The corrosion forms and conditions of each equipment are analyzed and summarized,and the potential corrosion points are found out.The suggestions for corrosion work and equipment overhaul are put forward.
作者 荐保志 JIAN Baozhi(PetroChina Guangdong Petrochemical Company,Jieyang,Guangdong,515200,China)
出处 《硫酸工业》 CAS 2020年第7期52-56,共5页 Sulphuric Acid Industry
关键词 催化裂化装置 腐蚀 检查 机理 定点测厚 FCC unit corrosion examination mechanisms spot thickness measurement
  • 相关文献

参考文献2

二级参考文献5

共引文献5

同被引文献5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部