摘要
本文主要对枣矿集团柴里煤矿现用电容器式无功补偿装置运行进行分析,并根据运行情况进行分析计算,提出升级选型主要性能参数,并对改造应用效果进行了分析总结。
This article mainly analyzes the operation of the current capacitor type reactive power compensation device in Chaili Coal Mine of Zao Mining Group,analyzes and calculates according to the operating conditions,proposes the main performance parameters of the upgrade and selection,and analyzes and summarizes the application effects of the transformation.
作者
宗曙光
苏亚伟
刘晓燕
ZONG Shu-guang;SU Ya-wei;LIU Xiao-yan(Chaili Coal Mine,Shandong Energy Zaozhuang Mining Group Co.,Ltd.,Tengzhou 277519,China)
出处
《价值工程》
2020年第26期217-218,共2页
Value Engineering
关键词
无功补偿
SVG选型
应用
reactive power compensation
SVG selection
application