摘要 本研究对农业部测定土壤中缓效钾含量的方法进行改进。结果表明,改进后的方法相对标准偏差<5%、相对误差-0.4^-2.2%,改进后的方法有较好的精密度和准确度,操作更加方便快捷。 In this study, the determination method for non-exchangeable potassium in soil, proposed by the Ministry of Agriculture, was improved. The result showed that relative standard deviation was less than 5% and relative error was -0.4%--2.2%. The improved method had better precision and accuracy, and the operation was more convenient and fast.
作者 邓万丽 DENG Wan-li(Guangzhou GRG Metrology&Test(Shenyang)Co.,Ltd.,Shenyang Liaoning 110168)
出处 《现代农业科技》 2020年第17期159-160,共2页 Modern Agricultural Science and Technology
关键词 土壤 缓效钾 热硝酸浸提-火焰光度计法 消解 soil non-exchangeable potassium hot nitric acid leaching-flame photometer method digestion