摘要
介绍了熔断器式隔离开关的结构及工作原理,针对提高熔断器式隔离开关使用类别,对其灭弧系统、触头系统进行改进,详细阐述了改进后的灭弧系统、触头系统设计原理,试验结果表明试品状态良好,性能提升显著。
The structure and working principle of fuse-switch-disconnector was introduced.Aiming at improving the use category of fuse-switch-disconnector,the arc extinguishing system and contact system were improved.The improved arc extinguishing system and contact system design principle were elaborated in detail.The experiment results show that the fuse-switch-disconnector is in good condition and the performance is improved significantly.
作者
刘辉
柳金淼
陈鑫浩
王兴利
高柏勇
LIU Hui;LIU Jinmiao;CHEN Xinhao;WANG Xingli;GAO Boyong(Zhejiang TENGEN Electric Co.,Ltd.,Whenzhou 325604,China)
出处
《现代建筑电气》
2020年第7期13-16,66,共5页
Modern Architecture Electric
关键词
熔断器式隔离开关
分断能力
灭弧室
静触头
使用类别
fuse-switch-disconnector
breaking capacity
arc extinguishing chamber
stationary contact
use category