期刊文献+

制氢装置提高产量及优化系统的实践

Practice of Increasing the Output and Optimizing the System of Hydrogen Production Unit
下载PDF
导出
摘要 北京首钢气体有限公司400 m^3/h制氢装置供气负荷逐年提高,而装置随着使用年限逐步增加,生产保供压力很大。通过改造装置的对流段换热器、余热废锅“塞阀”定位器、供水泵和引风机以及设备保温,使得装置工况稳定、经济,产量由338 m^3/h提高到420 m^3/h以上。 The gas supply load of the 400 m^3/h hydrogen production unit in Beijing Shougang Gas Co.has been increasing year by year.With the increase of service life of the unit,the pressure of production and supply guarantee has become very high.By reform⁃ing the convective section heat exchanger,waste heat boiler“plug valve”positioner,water supply pump,induced draft fan and equipment heat preservation,the operation condition of the unit has become stable and economical,and the output was increased from 338 m^3/h to more than 420 m^3/h.
作者 赵光明 马海龙 ZHAO Guangming;MA Hailong(Beijing Shougang Gases Co.,Ltd.,Shunyi,Beijing 101304,China)
出处 《冶金动力》 2020年第8期23-25,共3页 Metallurgical Power
关键词 制氢装置 改造 工况稳定 提高产量 hydrogen production unit revamping stable working condition increasing output