期刊文献+

抽取式颗粒物在线监测系统的测试分析

Test and Analysis of Extraction Particulate Matter On-Line Monitoring System
下载PDF
导出
摘要 针对固定排放污染源的颗粒物监测,阐述了抽取式颗粒物在线监测系统测试分析的具体步骤:首先在设备出厂前进行尘箱比对检定,校准确定传感器的一次项系数和常数项;其次在系统现场安装后通过调整工况的颗粒物质量浓度,手动采样称重计算颗粒物质量浓度,校准确定系统的一次项系数和常数项。通过比对两次校准结果,讨论了抽取式颗粒物在线监测系统现场应用的影响因素,指出K值和b值经过两次校准,抽取式颗粒物在线监测系统才能较真实地反映工况颗粒物质量浓度。 In view of the particulate matter monitoring of stationary emission pollution sources,the specific steps of test and analysis of extraction particulate matter on-line monitoring system are described:firstly,the dust box is compared and verified before the equipment leaves the factory,and the primary term coefficient and constant term of the sensor are determined by calibration;secondly,after the system is installed on site,the mass concentration of particulate matter is calculated by manual sampling and weighing by adjusting the mass concentration of particulate matter under working conditions,and the primary term coefficient and constant term of the system are determined by calibration.Based By comparison to the twice calibration results,the influencing factors of extraction particulate matter on-line monitoring system are discussed.It is pointed out that only after the K value and b value are calibrated twice can the mass concentration of particulate matter under working conditions be reflected more truly by extraction particulate matter on-line monitoring system.
作者 白慧宾 吕子啸 BAI Hui-bin;LYU Zi-xiao(Sinogreen Environmental Protection Technology Co.,Ltd.,Taiyuan 030024 China)
出处 《科技创新与生产力》 2020年第9期73-75,80,共4页 Sci-tech Innovation and Productivity
关键词 大气监测 烟气 颗粒物 颗粒物质量浓度 固定污染源 比对 校准 atmospheric monitoring flue gas particulate matter mass concentration of particulate matter stationary pollution source comparison calibration
  • 相关文献

参考文献3

二级参考文献13

共引文献48

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部