文章介绍了光伏发电系统站用接地变压器跳闸故障和光伏汇流箱经常烧直流熔断器故障的过程,分析了故障原因。并提出了处理措施。
This paper describes and analyzes the process,causes,treatment measures and effects of tripping fault of grounding transformer in photovoltaic power generation system and failure of DC fuse often burned in photovoltaic combiner box.
出处
《电力系统装备》
2020年第15期107-108,共2页
Electric Power System Equipment
关键词
光伏
接地
故障
熔断器
photovoltaic
grounding
fault
fuse