期刊文献+

高寒地区膏体尾矿库浮船泵站喷淋除冰系统应用

Application of spray deicing system for floating ship pump station of paste tailings reservoir in high cold area
下载PDF
导出
摘要 为解决高寒地区冬季浮船回水泵站不被冻结,保证尾矿库库内安全稳定运行,保证生产用水稳定供给,尾矿库车间与选矿厂相关人员多次讨论,多次实施再优化,最终确立了安全、稳定、可行的浮船泵站喷淋除冰系统应用方案。通过喷淋除冰系统优化应用,解决了高纬度高寒地区-40℃极寒天气,膏体尾矿库汇水区冰面厚度达800mm^1000mm时浮船回水泵站不被冻结。保证了尾矿库库内冬季回水安全稳定,保证了冬季生产用水稳定供给。 In order to solve the problem that the pontoon return water pumping station in the cold region is not frozen in winter,to ensure the safe and stable operation of the tailings pond,and to ensure the stable supply of production water,the tailings pond workshop and relevant personnel of the concentrator have discussed and re-optimized many times Finally,a safe,stable and feasible application plan for the spray deicing system of the floating ship pumping station was established.By optimizing the application of the spray de-icing system,the extreme cold weather of-40°C in high latitudes and cold regions is solved.When the ice surface thickness in the water area of the paste tailings pond reaches 800mm^1000mm,the pontoon return pump station is not frozen.It guarantees the safety and stability of the winter backwater in the tailings pond and the stable supply of production water in winter.
作者 周文彬 ZHOU Wen-bin(China National Gold Group Inner Mongolia Mining Co.,Ltd.,Manzhouli 021400,China)
出处 《世界有色金属》 2020年第11期263-264,共2页 World Nonferrous Metals
关键词 膏体 尾矿库 喷淋 paste tailings reservoir spray
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部