摘要
本文中作者介绍了一种并联电抗器感应电压试验的方法,此方法有别于以往传统的运用发电机作为电源进行供电的方式,可以有效杜绝试验时因补偿不当造成的发电机自励磁现象。
In this paper,the author introduces a method for testing the induced voltage of a shunt reactor.This method is different from the traditional method of using a generator as a power source to supply power.It can effectively eliminate the phenomenon of generator self-excitation caused by improper compensation during the test.
作者
谈翀
杨在葆
许涛
马华辉
王士君
韦良斌
TAN Chong;YANG Zai-bao;XU Tao;MA Hua-hui;WANG Shi-jun;WEI liang-bin(Shandong Power Equipment Co.,Ltd.,Jinan 250022,China)
出处
《变压器》
北大核心
2020年第8期45-48,共4页
Transformer
关键词
并联电抗器
感应电压
串联谐振
变频电源
Shunt Reactor
Induced voltage
Series resonant
Frequency power