摘要 根据新型冠状病毒肺炎疫情的需求及血液辐照仪的技术要求,采用蒙特卡罗软件FLUKA对一种2.5 MeV电子加速器X射线血液辐照仪的均整器和辐射防护进行了设计与仿真。仿真结果表明:均整后,照射区域内的吸收剂量率最大差异为7.6%,射线中心剂量率为均整前的57.6%,辐照仪整机外围5 cm处的剂量率最大为1μSv/h,优于血液辐照仪的使用标准;经估算,要保证血液吸收剂量为25 Gy,只需要照射4.5 min。 According to the current situation of the COVID-19 and the technical requirements of blood irradiators,this paper proposes a 2.5 MeV electron accelerator X-ray blood irradiator and designs its flattening filter and shielding structure.After detailed simulation design,the maximum difference of absorbed dose rate was about 7.6%,and the central absorbed dose rate was 57.6%as much as before.Meanwhile,the maximum dose rate at 5 cm outside the whole irradiator was 1μSv/h,which could fully meet the requirements of blood irradiator.It was estimated that only 4.5 minutes of exposure was needed to ensure the blood exposure dose of 25 Gy.
作者 周霖 陈浩 刘勇涛 许州 黄红 ZHOU Lin;CHEN Hao;LIU Yongtao;XU Zhou;HUANG Hong(Collaborative Innovation Center for Civil-Military Integration,Xihua University,Chengdu 610039 China;School of Science,Xihua University,Chengdu 610039 China;Institute of Nuclear Science and Technology,Sichuan University,Chengdu 610065 China)
出处 《西华大学学报(自然科学版)》 CAS 2020年第5期118-121,共4页 Journal of Xihua University:Natural Science Edition
基金 国防科工局项目核技术应用项目(科工二司[2020]343号)。
关键词 新型冠状病毒肺炎 电子加速器 均整器 屏蔽设计 血液辐照仪 coronavirus disease2019(COVID-19) electron accelerator flattening filter shielding design blood irradiator
  • 相关文献

参考文献13

二级参考文献61

共引文献45

同被引文献17

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部