期刊文献+

Guidelines for navigation-assisted spine surgery 被引量:1

原文传递
导出
摘要 Spinal surgery is a technically demanding and challenging procedure because of the complicated anatomical structures of the spine and its proximity to several important tissues.Surgical landmarks and fluoroscopy have been used for pedicle screw insertion but are found to produce inaccuracies in placement.Improving the safety and accuracy of spinal surgery has increasingly become a clinical concern.Computerassisted navigation is an extension and application of precision medicine in orthopaedic surgery and has significantly improved the accuracy of spinal surgery.However,no clinical guidelines have been published for this relatively new and fast-growing technique,thus potentially limiting its adoption.In accordance with the consensus of consultant specialists,literature reviews,and our local experience,these guidelines include the basic concepts of the navigation system,workflow of navigation-assisted spinal surgery,some common pitfalls,and recommended solutions.This work helps to standardize navigation-assisted spinal surgery,improve its clinical efficiency and precision,and shorten the clinical learning curve.
出处 《Frontiers of Medicine》 SCIE CAS CSCD 2020年第4期518-527,共10页 医学前沿(英文版)
  • 相关文献

参考文献4

二级参考文献49

  • 1Modi HN,Suh SW,Fernandez H,Yang JH,Song HR.Accuracy and safety of pedicle screw placement in neuromuscular scoliosis with free-hand technique.Eur Spine J 2008; 17:1686-1696.
  • 2Kosmopoulos V,Schizas C.Pedicle screw placement accuracy:a meta-analysis.Spine 2007; 32:E111-E120.
  • 3Rajasekaran S,Vidyadhara S,Ramesh P,Shetty AP.Randomized clinical study to compare the accuracy of navigated and non-navigated thoracic pedicle screws in deformity correction surgeries.Spine 2007; 32:E56-E64.
  • 4Arand M,Teller S,Gebhard F,Schultheiss M,Keppler P.Clinical accuracy of fluoroscopic navigation at the thoracic and lumbar spine.Z Orthop Unfall 2008; 146:458-462.
  • 5Citak M,Board TN,Sun Y,Look V,Krettek C,Hüfner T,et al.Reference marker stability in computer aided orthopedic surgery:a biomechanical study in artificial bone and cadavers.Technol Health Care 2007; 15:407-414.
  • 6Kim CW,Lee YP,Taylor W,Oygar A,Kim WK.Use of navigation-assisted fluoroscopy to decrease radiation exposure during minimally invasive spine surgery.Spine J 2008; 8:584-590.
  • 7Castro WH,Halm H,Jerosch J,Malms J,Steinbeck J,Blasius S.Accuracy of pedicle screw placement in lumbar vertebrae.Spine 1996; 11:1320-1324.
  • 8Liljenqvist UR,Halm HF,Link TM.Pedicle screw instrumentation of the thoracic spine idiopathic scoliosis.Spine 1997; 19:2239-2245.
  • 9Vaccaro AR,Rizzolo S J,Balderston RA,Allardyce TJ,Garfin SR,Dolinskas C,et al.Placement of pedicle screws in the thoracic spine.Part Ⅱ:An anatomical and radiographic assessment.J Bone Joint Surg Am 1995; 8:1200-1206.
  • 10Amiot LP,Lang K,Putzier M,Zippel H,Labelle H.Comparative results between conventional and computerassisted pedicle screw installation in the thoracic,lumbar,and sacral spine.Spine 2000; 25:606-614.