聚曙红Y修饰玻碳电极循环伏安法测定自来水中对苯二酚 被引量:2

Determination of hydroquinone in tap water by cyclic voltammetry with eosin Y polymer film modified glassy carbon electrode
下载PDF
导出
摘要 通过电聚合的方法将曙红Y修饰到玻碳电极表面,制备聚曙红Y修饰电极,该修饰电极对对苯二酚具有良好的电催化作用。利用循环伏安法研究了对苯二酚在该修饰电极上的电化学行为,在pH 5.0的乙酸盐缓冲溶液中,扫描速率为100 mV/s时,对苯二酚的浓度在5.0×10^-10~1.8×10^-6 mol/L范围内与其氧化峰电流线性关系良好,检出限为1.25×10^-10 mol/L。该电极测量值重现性相对标准偏差为1.03%~3.50%(n=6),自来水加标样品回收率为102.9%~109.7%。该方法可用于自来水中对苯二酚的测定。 The modified electrode was obtained by electropolymerizing eosin Y on a glassy carbon electrode,which exhibited outstanding electro catalytic activity towards the redox of p-benzenediol.The electrochemical behavior of p-benzenediol was explored by cyclic voltammetry.The peak currents of p-benzenediol showed a good linear relationship with the concentration in the range of 5×10^-10-1.8×10^-6 mol/L at the scan rate of 100 mV/s in acetate buffer solution with pH 5.The detection limit was 1.25×10^-10 mol/L.The relative standard deviation of reproducibility was 1.03%-3.50%(n=6),and the recovery of hydroquinone in standard additional tap water sample was 102.9%-109.7%.The proposed method can be used for determining the content of hydroquinone in tap water.
作者 王朝霞 高兆欧 邹娜 王学亮 WANG Zhaoxia;GAO Zhaoou;ZOU Na;WANG Xueliang(College of Chemistry and Chemical Engineering,Heze University,Heze 274015,China)
出处 《化学分析计量》 CAS 2020年第5期22-26,共5页 Chemical Analysis And Meterage
基金 山东省自然科学基金资助项目(No.ZR2017MB062)。
关键词 曙红Y 对苯二酚 循环伏安法 自来水 eosin Y hydroquinone:cyclic voltammetry tap water
  • 相关文献

参考文献2

二级参考文献33

  • 1侯明,张静.荧光红-曙红Y能量转移及荧光猝灭法测定痕量铜(Ⅱ)的研究[J].分析科学学报,2004,20(6):619-621. 被引量:14
  • 2魏永巨,康志敏,刘翠格,兰瑞家,王惠英.罗丹明B的共振散射光谱研究[J].光谱学与光谱分析,2004,24(12):1659-1662. 被引量:21
  • 3刘保生,高静,杨更亮.吖啶橙-罗丹明6G能量转移荧光猝灭法测定维生素B_(12)[J].光谱学与光谱分析,2005,25(7):1080-1082. 被引量:12
  • 4CHEN Guo-zhen(陈国珍),HUANG Xian-zhi(黄贤智),ZHENG Zhu-zi(郑朱梓),XU Jin-gou(许金钩),WANG Zunben(王尊本).Fluorometric Analysis2nd Ed.(荧光分析法(第二版))[M].Beijing(北京):Science Press(科学出版社),1990:122.
  • 5Eftink Maurice R,Ghiron Camillo A.Analytical Biochemistry[J],1981,114(2):199.
  • 6Ma C Q,Li K A and Tong S Y.Analytica Chimica Acta[J],1996,333(1-2):83.
  • 7Du H J, Ye J S, Zhang J Q, Huang X D, Yu C Z. J. Electroanal. Chem. , 2011, 650:209 -213.
  • 8Guo Q H, HuangJ S, Chen P Q, LiuY, Hou H Q, You T Y. Sens. Actuators B, 2012, 163:179-185.
  • 9Hua S, Wang Y H, Wang X Z, Xu L, Xiang J, Sun W. Sens. Actuators B, 2012, 168:27 -33.
  • 10He K Y, Wang X S, Meng X H, Zheng H T. Sens. Actuators B, 2014, 193:212 -219.