摘要
提出了一种基于六角图的三相三线电能表错误接线判断新方法。根据相位仪测量的电压、电流、相位角等数据,利用六角图法能迅速、便捷地判断出三相三线电能表错误接线的相别和电流方向,并验证测量的准确性,为电能表正确计量提供了支撑。
A new method for judging wrong wiring of three-phase three-wire kilowatt-hour meters based on hexagonal diagram is proposed.According to the voltage,current,phase angle and other data measured by the phase meter,the phase and current direction of the wrong wiring of three-phase three-wire kilowatt-hour meters can be quickly and conveniently judged using the hexagonal diagram method,and the accuracy of measurement is verified,which provides technology support for the correct measurement of kilowatt-hour meters.
作者
全妤
刘承东
金颀
鲁黎
QUAN Yu;LIU Chengdong;JIN Qi;LU Li(State Grid Wuhan Power Supply Company,Wuhan 430051,China;No.701 Research Institute of China State Shipbuilding Corporation Limited,Wuhan 430061,China)
出处
《国网技术学院学报》
2020年第4期23-26,共4页
Journal of State Grid Technology College
关键词
六角图法
三相三线
电能表
错误接线
hexagonal diagram method
three-phase three-wire
kilowatt-hour meters
error connection