摘要
地铁车站基坑开挖过程中,经常出现突涌、地下水无法抽干的情况,严重威胁着基坑自身及周边环境的安全。基此,分析了透水性地层的地铁基坑开挖过程遇到的抗突涌稳定、地下水无法抽干等问题原因,论证了地下水处理的必要性,并提出了有效解决途径及方法。
During the excavation of the subway station foundation pit,there are often sudden surges and the groundwater cannot be drained,which seriously threatens the safety of the foundation pit and the surrounding environment.Based on this,the reasons for the problems of anti-surge stability and groundwater cannot be drained during the excavation of foundation pits in permeable stratum are analyzed,the necessity of groundwater treatment is demonstrated,and effective solutions are proposed.
作者
刘干典
LIU Gandian(Fuzhou Rail transit Design Institute Co,Ltd,Fuzhou 350009)
出处
《福建建筑》
2020年第9期93-97,共5页
Fujian Architecture & Construction
关键词
地铁工程
基坑
抽水试验
地下连续墙落底
水平封底加固
Subway engineering
Foundation pit
Pumping test
Bottom falling of diaphragm wall
Horizontal back cover reinforcement