摘要
机房空调是用电大户,部分机房空调存在数量多、能耗大、局部热岛、个体运行没有自动协同以及效率低下等问题。通过空调群控精确送风技术在通信机房的应用,能将各自独立运行的机房专用空调联合成群进行管理控制,增加气流循环,较好地解决机房区域冷热不均、环境温度波动大、气流短路、设备启停频繁以及值班空调空耗电等问题,为机房节电节能和区域热岛问题解决提供了一种新方案。
The air conditioner in the machine room is a big power user,There are many air conditioners in some machine rooms,which consume a lot of energy,Low efficiency of individual operation without automatic collaboration.The application of air-conditioning group control precise air supply technology in communication room,It can manage and control the special air conditioners in the computer room independently in groups,After the air circulation is increased,the problems such as large fluctuation of temperature,short circuit of air flow,frequent start and stop of equipment and power consumption of air conditioner on duty are solved.It provides a new solution for power saving and energy saving of computer room and solving the problem of regional heat island.
作者
徐家胜
章小军
黄杰
XU Jia-sheng;ZHANG Xiao-jun;HUANG Jie(Lishui Branch of China Mobile Zhejiang Co.,Ltd.,Lishui 323000,China)
出处
《通信电源技术》
2020年第12期213-215,共3页
Telecom Power Technology
关键词
机房空调
独立运行
精确送风
air conditioner of machine room
ndependent operation
precise air supply