摘要
实验室超纯水机因内部结构复杂,拆卸困难,难以按电导率仪检定规程进行直接校准,文章介绍了纯水机的对比校准法并给出了测得值不确定度分析范例。
Due to the complicated internal structure of the laboratory ultra-pure water machine,it is difficult to disassemble,and it is hard to perform direct calibration according to the verification regulation of electrolytic conductivity meters. The article introduces the comparison calibration method of laboratory ultra-pure water machine and gives an example of uncertainty analysis of measurement results.
作者
刘苢
刘义平
杜好岗
张孝华
周恒
LIU Yi;LIU Yiping;DU Haogang;ZHANG Xiaohua;ZHOU Heng
出处
《计量与测试技术》
2020年第9期98-99,102,共3页
Metrology & Measurement Technique
基金
重庆市技术创新与应用示范项目(项目编号:cstc2018jszx-cyzdX0078)。
关键词
纯水机
校准方法
不确定度
pure water machine
calibration method
uncertainty