某钢轧厂房为钢筋混凝土排架结构,使用时发生火灾,导致失火区域及其周边结构构件受损。通过现场调查与检测,对厂房结构火灾后损伤状况进行分析,给出处理意见。
A steel rolling building is a reinforced concrete frame structure,fire broke out while in use,resulting in damage to the fire area and surrounding structural components.Through investigation and inspection,the damage condition of structure after fire was analyzed,and then give out the handling suggestions.
出处
《安徽冶金科技职业学院学报》
2020年第3期58-60,共3页
Journal of Anhui Vocational College of Metallurgy and Technology
关键词
钢轧厂房
火灾
处理意见
Steel rolling building
fire