摘要
文章对区域自动气象站双翻斗雨量传感器的现场核查方法进行了技术研究和探讨,并对现场核查时可能出现的问题提出了解决方案和建议。通过对核查结果超差的传感器进行调整,总结出了超差调整方法,为今后的日常维护提供了技术依据。
This paper makes a technical research and discussion on the on-site checking method of double tipper rainfall sensor in regional automatic weather station,and puts forward solutions and suggestions for the problems that may occur during the on-site checking.By adjusting the out-of-tolerance sensor,the out-of-tolerance adjustment method is summarized,which provides the technical basis for the daily maintenance in the future.
作者
金之川
郑亮
Jin Zhichuan;Zheng Liang(Sichuan Meteorological Observation Data Centre,Chengdu 610072;Sichuan Key Laboratory of Rainstorm,Drought and Flood disaster in Plateau and Basin,Chengdu 610072)
出处
《气象水文海洋仪器》
2020年第3期110-111,115,共3页
Meteorological,Hydrological and Marine Instruments
关键词
区域站
双翻斗雨量传感器
核查
超差调整
regional station
double tipper rainfall sensor
check
out-of-tolerance adjustment