摘要
超深且超厚的地下连续墙的接头是影响工程质量的关键因素。京沈客专京冀段十三标2号竖井地下连续墙工程使用#字形钢接头,很好地解决了超深且超厚的地下连续墙接头施工难题。
The joint of super deep and super thick underground continuous wall is the key factor affecting the engineering quality.Beijing-Shenyang special Beijing-Hebei section 13 standard 2 construction of super-deep and super-thick underground continuous wall joint is solved by using#zigzag steel joint.The construction problem of super deep and super thick underground continuous wall,is well solved.
作者
尧在雨
周伏萍
李文鹏
Yao Zaiyu;Zhou Fuping;Li Wenpeng(Jiangxi Geological Engineering(Group)Company,Nanchang 330029,China)
出处
《山西建筑》
2020年第20期76-78,共3页
Shanxi Architecture
关键词
超深地下连续墙
#字形钢接头
设计优化
super deep and super thick underground continuous wall
#zigzag steel joint
design optimization