期刊文献+

新型改良低预充体外循环系统的临床应用 被引量:6

A novel modified cardiopulmonary bypass with low prime volume-FUWAI-SAVE system
下载PDF
导出
摘要 目的评价新型改良低预充体外循环系统(FUWAI-SAVE系统)的临床效果。方法收集2015年1月1日至2018年1月31日在中国医学科学院阜外医院心脏外科体外循环下成人手术的患者资料,进行1∶1倾向性评分匹配回顾性队列研究,共匹配成功1070名FUWAI-SAVE组患者和1070名常规组患者。主要结局指标为围体外循环期红细胞输注率。结果匹配后两组患者基线数据无差异。FUWAI-SAVE组围体外循环期输血率明显下降(红细胞:34.8%vs.27.2%,P=0.0002;新鲜冰冻血浆:19.1%vs.12.6%,P<0.0001;血小板:0.9%vs.0.1%,P=0.0065)。FUWAI-SAVE组患者ICU医疗费用及住院总费用均明显低于常规组患者。两组患者其他术后结局无明显统计学差异。结论FUWAI-SAVE系统减少临床血制品使用并节约医疗花费。 Objective This study was evaluate the clinical outcomes of FUWAI-SAVE system and to share its application ex⁃perience.Methods This was a propensity-matched observational cohort study.Patients who underwent cardiac surgery in Fuwai Hos⁃pital discharged from 1/1/2015 to 31/1/2018 were evaluated.After 1:1 propensity-matching,a cohort with 1070 patients underwent conventional cardiopulmonary bypass(CPB)and 1070 patients underwent the FUWAI-SAVE system was created.The primary out⁃come was red blood cell transfusion rate.Results There was no significant difference between the two groups in demographic charac⁃teristics.Red cell blood transfusion was significantly decreased in the FUWAI-SAVE group(34.8%vs 27.2%,P=0.0002),and the same with fresh frozen plasma and platelet transfusion(19.1%vs 12.6%,P<0.0001;0.9%vs 0.1%,P<0.0001).Compared to the conventional CPB group,FUWAI-SAVE group exhibited less intensive care unit costs and in-hospital costs.No significant difference was observed regarding mortality between the two groups.Conclusion The FUWAI-SAVE system can reduce perioperative transfusion and save health care costs.
作者 刘刚 李勇男 刁晓林 高思哲 周纯 闫姝洁 王茜 滕媛 王建 吉冰洋 Liu Gang;Li Yongnan;Diao Xiaolin;Gao Sizhe;Zhou Chun;Yan Shujie;Wang Qian;Teng Yuan;Wang Jian;Ji Bingyang(Department of Cardiopulmonary Bypass,Fuwai Hospital,National Center for Cardiovascular Diseases,Chinese Academy of Medical Science and Peking Union Medical College,Beijing 100037,China)
出处 《中国体外循环杂志》 2020年第5期295-300,共6页 Chinese Journal of Extracorporeal Circulation
关键词 体外循环 低容量预充 FUWAI-SAVE系统 倾向性评分匹配分析 血液保护 心脏手术 Cardiopulmonary bypass Low prime volume FUWAI-SAVE system Propensity-matched study Blood conservation Cardiac surgery
  • 相关文献

参考文献4

二级参考文献23

  • 1Kiyama H, Imazeki T, Katayama Y, et al. Vacuum-assisted venous drainage in single-access minimally invasive cardiac surgery[J] .Artif Organs, 2003, 6(1): 20-4.
  • 2Colangelo N, Torracca L, Lapenna E, et al. Vacuum-assisted venous drainage in extrathoracic cardiopulmonary bypass management during minimally invasive cardiac surgery[J].Perfusion, 2006, 21(6): 361-5.
  • 3Murai N, Cho M, Okada S, et al. Venous drainage method for cardiopulmonary bypass in single-acees minimally invasive cardiac surgery: siphon and vaccum-assisted drainage[J]. Artif Organs,2005, 8(2): 91-4.
  • 4Shin H, Yozu R, Maehara T, et al. Vacuum assisted cardiopulmonary bypass in minimally invasive cardiac surgery: its feasibility and effects on hemolysis[J]. Artif Organs, 2000, 24(6): 450-3.
  • 5Taketani S, Sawa Y, Masai T, et al. A novel technique for cardiopulmonary bypass using vacuum system for venous drainage with pressure relief valve: an experimental study [J]. Artif Organs, 1998, 22(4): 337-41.
  • 6Vaughan P, Fenwick N, Kumar P. Assisted venous drainage on cardiopulmonary bypass for minimally invasive aortic valve replacement: is it necessary useful or desirable[J]. Interact CardioVasc Thorac Surg,2010, 10(5):868-871.
  • 7Carrier M, Cyr A, Voisine P, et al. Vacuum-assisted venous drainage doesnot increase the neurological risk[J]. Heart Surgery Forum, 2002, 5(6): 285-288.
  • 8Dibardino DJ, Allison AE, Vaughn WK, et at. Current ex- pectations for new horns undergoing the arterial switch opera- tion [J]. Ann Surg, 2004, 239(5) :588-596.
  • 9Daebritz SH, Nollert G, Sachweh JS, et al. Anatomical risk factors for mortality and cardiac mo rbidity after arterial switch operation [ J]. Ann Thorac Surg, 2000, 69(6) :1880-1886.
  • 10Cirri S, Negri L, Babbini M, et at. Haemolysis due to ac- tive venous drainage during eardiopulmonary bypass: cmopar- ison of two different techniques [ J ]. Perfusion, 2001, 16 (4) :313-318.