某型12kW自发电系统常见故障分析及处理

Analysis and Treatment of Common Faults in a 12 kW Generating System
下载PDF
导出
摘要 某型12 kW自发电系统无法正常供电,本文通过对自发电系统电子调速器不升速和取力器无输出,两个典型故障进行了研究分析,并建立了故障树,为用户在自发电系统遇到故障时,能做出及时的判断和应对措施提供帮助。 The power supply of a 12 KW self-generating power system is not normal. Through the research and analysis of the two typical faults of the self-generating power system, the electronic governor does not raise speed and the force taker does not output, and the fault tree is established to provide help for users to make timely judgment and response measures when the self-generating power system meets faults.
作者 韩俊 赵立锋 HAN Jun;ZHAO Li-feng(Institute of China Electronics Technology Corporation,Jiaxing,314001)
出处 《移动电源与车辆》 2020年第3期59-64,共6页 Movable Power Station & Vehicle
关键词 自发电系统 电子调速器 取力器 spontaneous electric system electronic governor force extractor