期刊文献+

基于初位移加载法和脉动法的单管通信塔模态测试与数值分析 被引量:1

Modal Test and Numerical Analysis of Single Tube Communication Tower Based on Pulsating Method and Initial Displacement Loading Method
下载PDF
导出
摘要 为了获得实际单管通信塔的动力特性,基于初位移加载法和脉动法对一单管通信塔结构进行了现场动力特性测试,获得了其前三阶频率和一阶阻尼比。利用SAP2000软件建立了该结构有限元模型,获得了结构计算的自振频率。对比结构实测和数值计算可知:初位移加载法和脉动法测试单管塔的动力特性基本一致;结构实测与数值计算自振频率基本一致;实测阻尼比比规范规定的阻尼比小。 In order to obtain the dynamic characteristics of the actual single tube communication tower the field dynamic characteristics of a single tube communication tower structure were tested based on the initial displacement loading method and pulsating method and the first three mode frequencies and the first mode damping ratio were obtained.The finite element model of the structure was established by software SAP2000 and the calculated natural frequencies were obtained.Compared with the actual measurement and numerical calculation of the structure it could be found that the dynamic characteristics of the actual single tube communication tower measured by the initial displacement loading method and pulsating method are basically the same.The measured frequencies of the structure are basically the same as the numerical calculated frequencies.The measured damping ratio is smaller than that specified in the code.
作者 沈之容 廖自来 虞德群 屠海明 Shen Zhirong;Liao Zilai;Yu Dequn;Tu Haiming(College of Civil Engineering Tongji University,Shanghai 200092 China;Anhui Sunac Real Estate Development Co.Ltd.,Hefei 230000 China;Heqin Communication Technology Co.Ltd.,Jinhua 321017 China;Tongji Architectural Design(Group)Co.Ltd.,Shanghai 200092 China)
出处 《特种结构》 2020年第5期48-51,55,共5页 Special Structures
关键词 单管通信塔 初位移加载法 脉动法 动力特性 数值模拟 Single tube communication tower Initial displacement loading method Pulsating method Dynamic characteristic Numerical simulation
  • 相关文献

参考文献8

二级参考文献62

共引文献83

同被引文献14

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部