摘要 为了更精确地测量硅异质结太阳电池的电性能参数,研究了有无偏置光对相对光谱响应测试的影响,分析了不同扫描时间、扫描方向、探针排遮挡、太阳电池测试台背面反射率等因素对测试的影响,确立了合理的硅异质结太阳电池的测试方法,对提高硅异质结电池测试准确度与精度提供了参考意义。 For accurate measurement of HJT solar cells,in this paper,the influences of the relative spectral response test with and without bias light are studied.The sweep time and direction,probe shading and the reflectance of measurement stage are analyzed.A reasonable HJT solar cells measurement method is established,which provides some reference for improving the measurement accuracy of HJT solar cells.
出处 《信息技术与标准化》 2020年第9期49-53,共5页 Information Technology & Standardization
基金 上海张江国家自主创新示范区专项发展资金,项目编号:ZJ2018-ZD-010 上海市科学技术委员会“双面发电太阳电池标定及检测技术研究”项目,项目编号:(17DZ1201100)。
关键词 硅异质结太阳电池 Ⅰ-Ⅴ曲线 校准 标准测试条件 silicon heterojunction solar cell Ⅰ-Ⅴ curve calibration standard test condition
  • 相关文献

参考文献2

二级参考文献24

  • 1蔡建文,李萍萍,徐传明,黄文浩.太阳电池测试系统及其参数匹配优化研究[J].光学精密工程,2007,15(4):517-521. 被引量:9
  • 2IEC 60904-1:Photovoltaic devices-Part 1:Measurement of photovoltaic current-voltage characteristics[S].Switzerland:International Electrotechnical Commission,2006.
  • 3IEC 60904-3:Photovoltaic devices-Part 3:Measurement principles for terrestrial photovoltaic(PV) solar devices with reference spectral irradiance data[S].Switzerland:International Electrotechnical Commission,2008.
  • 4GB/T 6495.1:光伏器件第一部分:光伏电流-电压特性的测量[S].北京:国家技术监督局,1996.
  • 5GB/T 6495.3:光伏器件第三部分:地面用光伏器件的测量原理及标准光谱辐照度数据[S].北京:国家技术监督局,1996.
  • 6ISO 21348:Space environment(natural and artificial)-Process for determining solar irradiances[S].Switzerland:International Organization for Standardization,2007.
  • 7EMERY K A.Solar simulators and I-V measurement methods[J].Solar Cells,1986,18(3-4):251-260.
  • 8GREULICH J,GLATTHAAR M,REIN S.Fill factor analysis of solar cells' current-voltage curves[J].Progress in Photovoltaics:Research and Applications,2010,18(7):551-515.
  • 9IEC 60904-4:Photovoltaic devices-Part 4:Reference solar devices-Procedures for establishing calibration traceability[S].Switzerland:International Electrotechnical Commission,2009.
  • 10OSTERWALD C R,ANEVSKY S,BUCHER K,et al..The world photovoltaic scale:an international reference cell calibration program[J].Progress in Photovoltaics:Research and Applications,1999,7(4):287-297.