火电厂混煤掺烧导致的水冷壁高温腐蚀泄漏分析 被引量:5

Analysis on High Temperature Corrosion Leakage of Water Wall Caused by Mixed Coal Combustion in Thermal Power Plant
下载PDF
导出
摘要 一次典型的由于混煤掺烧引发高温腐蚀失效案例,通过煤质变化情况与理化分析进行对比,高温下的高硫份和碱金属可加速水冷壁的腐蚀速度。电镜、金相分析等试验为更好地进行煤种掺配提供理论支持。 A typical case of high temperature corrosion failure caused by mixed coal blending.Through comparison of coal quality changes and physical and chemical analysis,high sulfur and alkali metals at high temperatures can accelerate the corrosion rate of water walls.Experiments such as electron microscopy and metallographic analysis provide theoretical support for better coal blending.
作者 昃刚 巩振泉 牟法海 董玲 Ze Gang;Gong Zhenquan;Mou Fahai;Dong Ling(Hebei Jiyan Energy Science and Technology Research Institute Co.,Ltd.,Shijiazhuang 050000,Hebei,China)
出处 《电站辅机》 2020年第3期16-19,共4页 Power Station Auxiliary Equipment
关键词 混煤掺烧 理化分析 高温腐蚀 扫描电镜 金相分析 mixed coal blending physical and chemical analysis high temperature corrosion scanning electron microscope metallographic analysis