摘要
本文依据《Design of Blast-Resistant Buildings in Petrochemical Facilities》(ACSE 41088),以具体工程的换流变阀侧套管洞口抗爆设计为例,针对抗爆设计荷载确定、抗爆窗结构计算、抗爆窗构造要点等方面加以介绍和分析,为以后类似工程提供适当的参考。
Based on"Design of Blast-Resistant Buildings in Petrochemical Facilities"(ACSE 41088),this paper takes the design and research of blast on valve side bushing hole of converter transformer of a specific project as an example,aims at introducing the determination of the blast load,the calculation of anti-blast window and the design points of anti-blast window.The author hopes to provide appropriate references for similar projects in the future.
作者
赵李源
ZHAO Li-yuan(Central Southern China Electric Power Design Institute Co.,Ltd.of CPECC,Wuhan 430071,China)
出处
《价值工程》
2020年第30期148-150,共3页
Value Engineering
关键词
抗爆窗
换流变压器
洞口
抗爆设计
anti-blast window
converter transformer
hole
anti-blast design