摘要
室内散热属于显热得热,采用冷负荷系数计算其形成的空调冷负荷。分析了冷负荷系数构成原理,分析了两种典型情形冷负荷系数确定方法,工作时间不连续散热量恒定和工作时间连续散热量不恒定;室内散湿属于潜热得热,得热量全部形成瞬时冷负荷。分析得出水蒸发所需热量来自室内空气的散湿不会形成潜热冷负荷,因此计算冷负荷时要根据散湿热量来源对其进行分类分析。
Indoor heat dissipation belongs to sensible heat gain,and the air-conditioning cooling load is calculated by cooling load coefficient.The principle of cooling load coefficient is analyzed.Two methods to determine the cooling load coefficient under special conditions are analyzed.The working time is discontinuous and the heat dissipation is constant.Indoor moisture dissipation belongs to latent heat gain,and all the heat obtained form instantaneous cooling load.It is concluded that the heat needed for water evaporation comes from indoor air,and the latent heat cooling load will not be formed.Therefore,the cooling load should be classified and analyzed according to the heat source of moisture dissipation.
作者
杨宏军
赵仕琦
杨艺
YANG Hong-jun;ZHAO Shi-qi;YANG Yi(School of Mechanical and Power Engineering,Guangdong Ocean University,Zhanjiang 524088,China)
出处
《应用能源技术》
2020年第9期1-4,共4页
Applied Energy Technology
基金
广东海洋大学2019年专业核心课培育——通风与空调工程(571119084)
2019年度广东海洋大学校级质量工程暨“冲一流”与“创新强校工程”一般类教改项目(校教务(2019)86号)
广东省创新强校工程专项资金国家级一流专业培育项目——建筑环境与能源应用工程专业(230419127)。
关键词
冷负荷系数
显热冷负荷
潜热冷负荷
室内散湿源
无源散湿
cooling load coefficient
sensible cooling load
latent cooling load
indoor moisture source
passive moisture dispersion