国产六维导板辅助无牙颌种植手术的精度分析 被引量:3

Accuracy of 6D computed-derived implant guides made in China for dental implant surgery in edentulous patients
下载PDF
导出
摘要 目的:评估国产六维数字化种植导板的精度,为临床应用提供减小偏差的方法和依据。方法:采用3D打印制作种植导板,应用于无牙颌患者,辅助外科植入,测量种植体术前设计和术后实际位置之间的偏差。选择16例无牙颌患者,测量172个植入位点。其中,10例患者上颌骨植入6颗植体,下颌骨植入4颗植体;6例患者上、下颌骨各均植入6颗植体;14例患者、28颗植体为倾斜植入。将术前锥形束CT(CBCT)数据导入国产六维齿科牙种植设计软件,设计和制作导板;应用数字化导板辅助植入手术;术后拍摄CBCT并导入六维软件进行三维重建,并与术前设计进行配准;将配准模型导出到Geomagic Studio软件进行分析,得出术前设计和植入后种植体的位置偏差,分析导板辅助下种植手术精度。采用SPSS 25.0软件包对样本进行配对t检验及单因素方差分析。结果:种植体顶部中心点距离偏差为(0.83±0.27)mm,水平向偏差为(0.60±0.21)mm;种植体底部中心点距离偏差为(1.11±0.35)mm,垂直向偏差为(0.45±0.19)mm;角度偏差为(3.16±1.73)°。结论:六维数字化导板能够显著提高无牙颌患者种植手术精度和效率,并获得较好的远期临床效果。临床设计时须考虑偏差,规避风险和并发症。 PURPOSE:To evaluate the accuracy of 6D computed-derived implant guides made in China,in order to provide methods and basis for reducing deviation.METHODS:3D rapid prototyping technique was used to fabricate implant guides for auxiliary surgical implantation in edentulous patients,and the position deviation between the preoperative design and the actual implant was measured.Sixteen edentulous patients with 172 implantation sites were measured.In 10 patients,six implants were implanted in the maxilla,4 implants in the mandible,and 6 implants were implanted both in the maxilla and mandible of 6 patients.A total of 28 implants were tilted implant in 14 patients.Preoperative cone-beam CT(CBCT)data were imported into the 6D Dental Planning Software to design and make the implant guides.Digital guides were used to assist implant placement.Preoperative design and postoperative CBCT were imported into the software for 3D reconstruction and registration,and then exported to Geomagic Studio software for analysis to obtain the deviation between the preoperative design and the implantation,so as to analyze the accuracy of the guides.The differences were analyzed by SPSS 25.0 software package with paired t-test and single factor analysis of variance.RESULTS:The distance deviation of implant neck center point was(0.83±0.27)mm and the horizontal deviation was(0.60±0.21)mm.The distance deviation of implant bottom center point was(1.11±0.35)mm,and the vertical deviation was(0.45±0.19)mm.The angle deviation was(3.16±1.73)°.CONCLUSIONS:The 6D computed-derived implant guides made in China can improve the accuracy and efficiency of implant surgery for edentulous patients and obtain a better long-term clinical effect to meet clinical requirements well.Since the deviation is similar to other implant guide plate systems that reported aborad,it must be taken into account in the process of clinical design,in order to avoid risks and unnecessary complications.This method is worthy of wide clinical application.
作者 涂业颖 周健 于艳春 樊明星 泮海松 林海燕 TU Ye-ying;ZHOU Jian;YU Yan-chun;FAN Ming-xing;PAN Hai-song;LIN Hai-yan(Stomatological College of Zhejiang Chinese Medicine University,Hangzhou 310053;Hangzhou Stomatology Hospital,Hangzhou 310000;Hangzhou 6D Dental Medical Technology Co,Ltd.Hangzhou 310023,Zhejiang Province,China)
出处 《上海口腔医学》 CAS CSCD 北大核心 2020年第5期504-508,共5页 Shanghai Journal of Stomatology
基金 浙江省医药卫生科技项目(2020374061)。
关键词 国产六维导板 无牙颌 种植 精度 偏差 锥形束CT 6D computed-derived implant guides made in China Edentulous jaw Dental implant Accuracy Deviation Cone-beam CT
  • 相关文献

同被引文献20

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部