期刊文献+

新建660 MW机组烟气余热利用方案及经济性分析 被引量:2

Economical Comparison of Different Systems for Waste Heat Recovery From Flue Gas in a New 660 MW Power Plant
下载PDF
导出
摘要 燃煤电厂锅炉尾部烟道加装低温省煤器可以有效地回收烟气余热,提高机组运行效率。以国外某新建660 MW机组为工程应用背景,提出了两种烟气余热利用方案,经济性分析结果表明:设置一级布置在除尘器前的低温省煤器方案优于设置二级布置在除尘器前和引风机后的低温省煤器方案。 Arrangement with low temperature economizer can effectively recovery waste heat from flue gas,improving the efficiency of power plant.Two systems for waste heat recovery from flue gas are proposed for a new 660 MW foreign power plant.Results show that using one low temperature economizer arranged in front of the precipitator is superior to using two low temperature economizers arranged in front of the precipitator and after induced draft fan respectively through the economical comparison.
作者 王光磊 高绪栋 王宗群 纪兴林 WANG Guanglei;GAO Xudong;WANG Zongqun;JI Xinglin(Shandong Electric Power Engineering Consulting Institute Co.,Ltd.,Jinan 250013,China)
出处 《山东电力技术》 2020年第10期78-80,共3页 Shandong Electric Power
基金 国家核电技术公司科研B类课题(SNPTC-C04-2018-0006)。
关键词 余热利用 低温省煤器 净现值法 动态投资回收期 waste heat recovery low temperature economizer net present value method dynamic investment payback period
  • 相关文献

参考文献3

二级参考文献37

共引文献51

同被引文献30

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部