摘要 提出了一种结合光镊技术与微流控芯片的人血红细胞变形性高通量检测方法,用于红细胞变形性的统计学准确表征。首先,利用光阱力与流体粘滞阻力的共同作用实现红细胞的有效拉伸变形;然后,利用图像处理方法对单细胞变形前后的特征参量进行提取,得到面积和周长变形指数;最后,进行统计学分析,并利用平均变形指数参量(、)对红细胞的变形性进行表征。搭建了高通量检测系统,通过大量实验得到了最优实验条件;并利用具有不同变形性的3组样本进行了统计学验证实验。结果表明,最小区分量为9.71%,8通道结构的检测通量约为370个/min。高通量检测及表征方法可以实现不同变形性红细胞的统计学有效区分,为其他类型样本的高通量变形性分析提供了解决思路。 A high throughput measurement method of human red blood cells(RBCs)deformability combined with optical tweezers technology and the microfluidic chip was proposed to accurately characterize the deformability of RBCs statistically.Firstly,the effective stretching deformation of RBCs was realized by the interaction of photo-trapping force and fluid viscous resistance.Secondly,the characteristic parameters before and after the deformation of the single cell were extracted through the image processing method to obtain the deformation index of area and circumference.Finally,statistical analysis was performed,and the average deformation index parameters(,)were used to characterize the deformability of RBCs.A high-throughput detection system was built,and the optimal experimental conditions were obtained through a large number of experiments.Three groups of samples with different deformability were used for statistical verification.The results showed that the smallest cell component was 9.71%,and the detection flux of 8-channel structure was about 370 cells/min.High-throughput detection and characterization methods can effectively distinguish different deformed RBCs statistically,which provides a solution for high-throughput deformation analysis of other types of samples.
作者 张朦 孟晓辰 祝连庆 ZHANG Meng;MENG Xiaochen;ZHU Lianqing(Beijing Key Laboratory for Optoelectronic Measurement Technology,Beijing Laboratory of Biomedical Testing Technology and Instruments,Beijing Information Science and Technology University,Beijing 100101,P.R.China)
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2020年第5期848-854,共7页 Journal of Biomedical Engineering
基金 国家自然科学基金(61605010) 北京信息科技大学促进高校内涵发展科研水平提高项目(521191092) 北京信息科技大学“勤信人才”培育计划(QXTCP C201903)。
关键词 红细胞变形性 微流控芯片 光镊 高通量检测 red blood cells deformability microfluidic chip optical tweezer high throughput detection
  • 相关文献

参考文献13

二级参考文献109

共引文献84

同被引文献8

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部