期刊文献+

空预器压差大的原因分析及解决措施

Analysis on the Cause and Countermeasure of Large Pressure Difference of Air Preheater
下载PDF
导出
摘要 文章分析了常州电厂630 MW燃煤机组空气预热器烟气侧进出口压差大的原因,提出了运行优化调整的措施,对比了在线高压水冲洗、拆包冲洗和升温处理3种方法治理空预器局部堵塞的效果,为解决空预器压差大问题提供参考。 This paper introduces the reasons for the large inlet and outlet pressure difference of the air preheater(hereinafter referred to as air preheater)of 630 MW coal-fi red units in Changzhou Power Plant,puts forward the measures of operation optimization adjustment,compares the effect of three methods of on-line high pressure water washing,unpacking washing and heating treatment on local blockage of air preheater,and provides a useful reference for solving the problem of large pressure difference of air preheater.
作者 吴子崴 Wu Zi-wei
出处 《电力系统装备》 2020年第19期49-50,共2页 Electric Power System Equipment
关键词 空预器 压差大 air preheater large pressure difference
  • 相关文献

参考文献3

二级参考文献6

共引文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部