期刊文献+

350 MW机组机电联锁回路的优化

Optimization of Electromechanical Interlocking Circuit for 350 MW Unit
下载PDF
导出
摘要 针对某电厂350 MW机组汽轮机-电气(简称机电)联锁开出、开入回路存在违反国家能源局《防止电力生产事故的二十五项重点要求》和某集团分公司防止汽轮机超速管理重要要求的问题,通过机组机电联锁开出、开入回路优化前、后的对比,提出了回路具体优化的改进方法,提高了机组机电联锁开出、开入回路的可靠性,降低了汽轮机发生超速故障的可能性,保证了机组安全稳定运行。 The output and input circuits of steam turbine-electrical(electromechanical)interlock of a 350 MW unit in a power plant have violated the 25 key requirements for preventing power production accidents and the management requirements for preventing turbine overspeed of a group company.Based on the comparison of the output and input circuit of the units electromechanical interlock before and after the optimization,the improvement method of the circuit optimization is put forward.It improves the reliability of the units electromechanical interlock output and input circuit,reduces the possibility of turbine overspeed fault,and ensures the safe and stable operation of the unit.It has a certain reference significance for other power plant units to improve the output and input circuit of electromechanical interlocking.
作者 王济娟 赵利权 宋爽 WANG Jijuan;ZHAO Liquan;SONG Shuang(I.Datang International Huludao Thermal Power Co.,Ltd.,Huludao 125000,Chian;State Grid Jilin Electric Power Co.,Ltd.Electric Power Research Institute,Changchun 130021,China;State Grid Changchun Power Supply Company,Changchun 130021,China)
出处 《吉林电力》 2020年第5期51-52,56,共3页 Jilin Electric Power
关键词 继电保护 汽轮机-电气联锁 超速 electromechanical interlock steam turbine-electrical interlock overspeed