摘要 根据GB/T 35263—2017《纺织品接触瞬间凉感性能的检测和评价》对纺织品接触凉感性能进行测试,详细分析和评定了测试过程中影响结果的各个不确定度分量。结果表明,不确定度首先来自重复测量,其次是检测仪器引入的不确定度。在检测时,须严格按规划操作,严格控制环境温度,提高多次检测的稳定性。 According to GB/T 35263—2017“testing and evaluation of the instantaneous cooling sensitivity of textiles”,the contact coolness performance of textiles was tested,and the uncertainty components influencing the results were analyzed and evaluated in detail.The results show that the uncertainty comes from repeated measurement,followed by the uncertainty of instrument introduce.The operation must be carried out in strict accordance with the plan and the environmental temperature should be strictly controlled to improve the stability of multiple tests.