期刊文献+

Analysis of operational parameters affecting denitrification rate of sintering flue gas in cross-flow activated coke purification facility

原文传递
导出
摘要 The denitrification rate of the cross-flow activated coke flue gas purification facility varies with operational parameters. According to the simulated experiments, the denitrification rate with the height drop of the denitrification unit experiences 100%, rapid decreasing, and gradual rising to the equilibrium. According to the correlation analysis results based on production data, several operational parameters affecting the denitrification rate have been obtained. The denitrification rate has negative relationships with the activated coke bed temperature, the flue gas flow, the H2O content, the SO2 content and the NH3 slip, and has positive relationships with the O2 content, the NOx content, the NH3–NOx molar ratio, the flue gas pressure and the regeneration temperature. Properly increasing the sintering air leakage or the cooling air added into flue gas is beneficial to increase the denitrification rate. Priority should be given to O2, NH3–NOx molar ratio and flue gas flow to improve the denitrification rate. Additionally, a linear model, which had been validated, was developed and can be used to predict and control the denitrification rate.
出处 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2020年第8期887-897,共11页
基金 The authors would like to thank the financial support of Fundamental Research Funds for the Central Universities(Grant No.FRF-IC-18-010).