期刊文献+

Responses of HFR-LWC beams under close-range blast loadings accompanying membrane action

下载PDF
导出
摘要 The load-carrying capacities and failure patterns of reinforced concrete components can be significantly changed by membrane effects.However,limited work has been carried out to investigate the blast resistance of Hybrid Fiber Reinforced Lightweight Aggregate Concrete(HFR-LWC)members accompanying membrane action.This paper presents a theoretical approach to quantitatively depicting the membrane behavior and its contribution on the behavior of HFR-LWC beams under close-range blast loadings,and the suitability of the proposed model is validated by a series of field tests.An improved Single-Degree-of-Freedom(SDOF)model was employed to describe the dynamic responses of beam-like members under blast loadings accompanying membrane action,where the mass-load coefficient is determined according to the nonuniformly distributed load induced by close-range explosion,and the membrane action is characterized by an in-plane(longitudinal)force and a resisting moment.The elastoplastic and recovery responses of HFR-LWC beams under the combined action of blast load and membrane force were analyzed by the promoted model.A specially built end-constrain clamp was developed to provide membrane action for the beam member when they are subjected to blast load simultaneously.It is demonstrated that the analytical displacement-time histories are in good agreement with experimental results before peak deflections and that the improved SDOF model is an acceptable tool for predicting the behavior of HFR-LWC beams under blast loadings accompanying membrane action.
出处 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2020年第6期1167-1187,共21页 Defence Technology
基金 the financial support from the National Natural Science Foundation of China(Grant:51578541,51378498) the Natural Science Foundation of Jiangsu Province(Grant:BK20141066).
  • 相关文献

参考文献7

二级参考文献51

  • 1李伟.无锡地铁1号线上盖物业开发停车场的消防设计[J].铁道标准设计,2012,32(6):135-137. 被引量:10
  • 2Wei Sun, Huisu Chen, Xin Luo, and Hongpin Qian, The effect of hybrid and expansive agent on the shrinkage and permeability of high-performance concrete[J],Cement and concrete research,2003 (31) :595-601
  • 3Weller A D. Broadgate phase 8:Fire,22 June 1990 [R].Summary report of damage and repair, Building Research Establishment PD 21/92,Jan. 1992.
  • 4Bailey C G, Lennon T, Moore D B. The behaviour of full-scale steel framed buildings subjected to compartment fires [ J ]. The Structural Engineer, 1999,77 ( 8 ) : 15-21.
  • 5Wang Y C. Tensile membrane action and fire resistance of steel framed buildings [ C ] // Proceedings of the 5th International Symposium on Fire Safety Science. Melbourne, Australia:International Association for Fire Safety Science, March 1997.
  • 6Johansen K W. Yield line theory [ M ]. Published by Cement and Concrete Association, London, 1962.
  • 7Brotchie J F , Holley M J. Membrane action in slabs, in cracking, deflection and ultimate load of concrete slab systems [ M ]. ACI Special Publication 30, Detroit : American Concrete Institute, 1971 : 345-377.
  • 8Andre Coin. Rotules plastiques des dalls soumises au feu [ R ]. Annales de l'institut technique du batiment et des travaux publics, No,359, Paris, Mars 1978.
  • 9Boutin J P. Pratique du calcul de la resistance au feu des structures en beton [ R ]. Edited by Eyrolles. Collection, Paris:Les Dossiers de la Construction, 1983.
  • 10Gillie M, Usmani A, Rotter M, O'Connor, M. Modeling of heated composite floor slabs with reference to the Cardington experiments[J].Fire Safety Journal, 2001,36 ( 8 ) : 745-767.

共引文献56

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部